SureCross™ DX81P6 FlexPower™ Supply Module
Delivers and manages dc voltage from six 3.6V dc lithium primary batteries
Features
•
•
Wireless solution for powering a FlexPower™ Node and sensor devices
Unique power management system to run the FlexPower Node and a device through
switched power outputs for up to ten years, depending on the power requirements of
the device and required update rates
•
•
Six 3.6V dc lithium “D” cell batteries
IP67 sealed enclosure
FlexPower systems allow for a true wireless solution as the Node can be powered by battery
power (3.6 to 5.5V dc). Battery life is application specific. Contact Banner Engineering’s
application engineers for a battery life calculation for your specific application.
For additional information and a complete list of replacement parts, please refer to Banner
Models
Model
Power
Batteries
Cable
DX81P6
3.6V dc Battery
Six 3.6V lithium “D” Cells
5-pin Euro Pigtail QD
WARNING . . . Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A
sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner
Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
Printed in USA
01/08
P/N 131628 rev. B
SureCross™ DX81P6 FlexPower™ Supply Module
Specifications
General
Mounting
#1/4 or M7 (M7 hardware included)
M7 fasteners – Max. Tightening Torque
Case Material
0.56 N•m (5 in•lbf)
Polycarbonate
Weight
0.98 kg (2.15 lb.)
External Cable Glands
Cable Glands, Max Tightening Torque
Connections
One 1/2 NPT type
0.56 N•m (5 in•lbf)
PVC cable; 5-pin Euro-style 150mm Pigtail QD
114,000 mA hours
Estimated Life
Environmental
Environmental Rating*
Operating Temperature**
Operating Humidity
Radiated Immunity
IEC IP67; NEMA 6
-40 to +85° C (Electronics)
95% max. relative (non-condensing)
10 V/m, 80-2700 MHz (EN61000-6-2)
IEC 68-2-6 and IEC 68-2-7
Shock and Vibration
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10-60 Hz
*
Please refer to the SureCross™ DX80 Wireless I/O Network product manual, Banner p/n 132607, for installation and waterproofing instructions.
** Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device.
Banner Engineering Corp. • Minneapolis, MN U.S.A
P/N 131628 rev. B
3
SureCross™ DX81P6 FlexPower™ Supply Module
Dimensions
195.9mm [7.71"]
148.1mm [5.83"]
87.6mm [3.45"]
55.9mm [2.20"]
138.2mm [5.44"]
20.1mm [0.79"]
The manufacturer does not take responsibility
for the violation of any warning listed in this
document.
Always use lightning arrestors/surge protection with all remote antenna systems to avoid invalidating the
Banner Engineering Corp. warranty. No surge protector can absorb all lightning strikes. Do not touch the
SureCross device or any equipment connected to the SureCross device during a thunderstorm.
CAUTION . . .
Make no modifications to this
product.
WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year.
Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be
defective at the time it is returned to the factory during the warranty period. This warranty does not cover
damage or liability for the improper application of Banner products. This warranty is in lieu of any other
warranty either expressed or implied.
Any modifications to this product not expressly
approved by Banner Engineering could void the
user’s authority to operate the product. Contact
the Factory for more information.
All specifications published in this document are subject to change. Banner reserves the right to modify the specifications of products, prior to their order, without
notice. Banner Engineering reserves the right to update or change documentation at any time. For the most recent version of any documentation, please refer to our
P/N 131628 rev. B
|